Hot Tub / Spa Electrical Codes for 2011

PRINTABLE VERSION

Gunther Home Inspections, Hot Tub Inspections

ELECTRICAL WIRING REQUIREMENTS FOR HOT TUBS / SPAS
2008 National Electrical Code / 2010 Residential Code of New York State

SPA OR HOT TUB. A HYDROMASSAGE POOL, OR TUB FOR RECREATIONAL OR THERAPEUTIC USE, NOT LOCATED IN HEALTH CARE FACILITIES, DESIGNED FOR IMMERSION OF USERS, AND USUALLY HAVING A FILTER, HEATER, AND MOTOR-DRIVEN BLOWER. THEY ARE INSTALLED INDOORS OR OUTDOORS, ON THE GROUND OR SUPPORTING STRUCTURE, OR IN THE GROUND OR SUPPORTING STRUCTURE. GENERALLY, A SPA OR HOT TUB IS NOT DESIGNED OR INTENDED TO HAVE ITS CONTENTS DRAINED OR DISCHARGED AFTER EACH USE.

1) Hot Tub / Spa Wiring Method and Receptacles (Outlets)

a. Maintenance Disconnect - A disconnect is required for all ungrounded electrical wires (except for lighting). It must be at least 5’ but not more that 50’ from the water’s edge, readily accessible, and within sight of the Hot Tub / Spa.
b. The outlet(s) that supply a Hot Tub / Spa must be Ground-Fault Circuit Interrupter (GFCI) protected.
c. Indoors Hot Tubs & Spas
i. At least one (1) convenience receptacle must be located between 6’ and 10’ from the inside wall of the Hot Tub / Spa and be GFCI Protected (Existing receptacle OK and wired with any approved wiring method).
d. Outdoors Hot Tubs & Spas
i. At least one (1) convenience receptacle must be located between 6’ and 20’ from the inside wall of the Hot Tub / Spa and be GFCI Protected (Existing receptacle OK and wired with any approved wiring method).
ii. Liquidtight flexible metal or nonmetallic conduit is permitted in lengths of not more than 6’.
iii. A listed packaged hot tub / spa installed outdoors that is GFCI protected shall be permitted to be cord and plugconnected provided that such cord does not exceed 15 feet in length.
iv. Outdoor receptacles must have a weatherproof cover where exposed to the weather (In-use type cover required on used, unattended, receptacles in wet locations).


2) Bonding The Hot Tub / Spa

a. All metal parts & surfaces within 5’ of the Hot Tub / Spa must be bonded together using a #8 (or larger) solid copper wire and
connections must be non-corrosive.
b. Outdoor Hot Tubs / Spas with nonconductive shells must have a #8 (or larger) solid, bare copper wire 18”-24” from the inside
hot tub wall under the perimeter surface 4”-6” below the final grade and connected to a metal part of the pump motor.

3) Lighting (other than underwater applications) (if any)

a. All non-GFCI protected lights and ceiling fans within 5’ of the inside wall of the Hot Tub / Spa must be at least 12’ above the maximum water level of the Hot Tub / Spa.
b. All GFCI protected lights and ceiling fans within 5’ of the inside wall of the Hot Tub / Spa must be at least 7 ½’ above the maximum water level of the Hot Tub / Spa.
c. Exception - Lights that are within 5’ of the inside wall of the Hot Tub / Spa and less than 7 ½’ above the water level are only acceptable if they meet the following:
i. Recessed Lights - GFCI protected with a glass or plastic lens, nonmetallic or electrically isolated metal trim, and suitable for damp locations.
ii. Surface-Mounted Lights - GFCI protected with a glass or plastic globe, a nonmetallic body, or a metallic body isolated from contact, and suitable for damp locations.

4) Other

a.
Building Permits are required. Always secure a Building Permit from your municipality prior to beginning work.
b. Indoor Hot Tubs / Spas wall switches must be a minimum 5’ from the inside wall of the Hot Tub / Spa.
c. Outdoor Hot Tubs check for overhead wires within 10’ of the Hot Tub. (Must be 22 ½’ above water level & not allowed in many towns)
d. All Hot Tubs / Spas, other than in a single family residence, must have an emergency shutoff between 5’-50’ & within sight.

Check with your local building department for any additional requirements and/or restrictions prior to beginning work

PRINTABLE VERSION

 

 

 


Should you have questions, problems or
suggestions regarding our web site please contact our WebMaster

[ ABOUT GHI HOME ][ HOME INSPECTION ][ INSPECTION FEES ][ SET AN APPOINTMENT] [RADON TESTING ][ PEST INSPECTIONS ][ CUSTOMER TESTIMONIALS ][ FEATURE TOPICS] [ BROKERS AND REAL ESTATE AGENTS ][SCHEDULE APPOINTMENT ON-LINE][CONTACT US ]

Gunther Home Inspections, Inc.
Voice 585-349-3900 - Fax 585-349-3834
2767 Dewey Avenue - Rochester, NY 14616 - www.InspectNY.com
NYS# 16000005972
 © 1998-2012 Gunther Home Inspections, Incorporated